Tripp-lite BP240V10RT3U Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Narzędzia Tripp-lite BP240V10RT3U. Tripp Lite BP240V10RT3U User Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 17
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 0
Owner’s Manual
1111 W. 35th Street • Chicago, IL 60609 USA
Customer Support: (773) 869-1234 • Application Services: (773) 869-1236
www.tripplite.com
Copyright ©2002 Tripp Lite. All rights reserved.
SmartOnline
Tower/Rackmount Power Protection
SU6000RT3UPM • SU10KRT3UPM
Tower/Rackmount UPS Systems
SU6000XFMR • SU10KXFMR
Tower/Rackmount Isolation Transformers
BP240V7RT3U • BP240V10RT3U
Tower/Rackmount Battery Packs
Important Safety Warnings
Mounting
Connection
Features
Operation
Service/Warranty and Insurance
Specifications
Español/Français/Deutsch
2
3
6
9
13
16
17
18/35/52
Przeglądanie stron 0
1 2 3 4 5 6 ... 16 17

Podsumowanie treści

Strona 1 - Owner’s Manual

Owner’s Manual1111 W. 35th Street • Chicago, IL 60609 USACustomer Support: (773) 869-1234 • Application Services: (773) 869-1236www.tripplite.comCopyr

Strona 2 - Important Safety Warnings

10NORMALBYPASSHardwire your isolation transformer’s UPS connector toyour UPS’s input and output.Remove the tops of the boxes covering the UPS’s and tr

Strona 3 - Mounting

11ConnectioncontinuedConnect external battery pack(s) to your UPSYour UPS has no internal batteries and must be connected to at least one externalbatt

Strona 4

12Turn input to the UPS ONIf the UPS is connected to a transformer, turn the transformer’s UPS and LoadBreakers ON. Turn the UPS’s Input Circuit Break

Strona 5

13DIAGNOSTIC MODEAC/DC OKDIAGNOSTIC MODETESTING INVERTERON BATTERY MODELOAD = XXX% X.XXKWOperationWhen you turn the UPS ON, it will enter Diagnostic M

Strona 6 - Features

14OperationcontinuedDuring normal operation, the first line of your LCD Display shows which operating mode your UPS is in: Online, Economy, On Battery

Strona 7

15OperationcontinuedWhile in Bypass Mode, the UPS monitors its input voltage and passes that input power along to connected equipment. The UPS will no

Strona 8

16Service/Warranty and InsuranceYour SmartOnline UPS is covered by the 2-year limited warranty period described below. A variety of service contracts

Strona 9

17SpecificationsSpecifications are for UPS, Isolation Transformer, and one battery pack.Model SU6000RT3U SU10KRT3U InputUPS Input Voltage 156V~276V Si

Strona 10 - Connection

2Important Safety WarningsSAVE THESE INSTRUCTIONS. This manual contains important instructions and warnings that should be followed during the install

Strona 11

3Mounting1Single Unit Installation123ABCBEDF4GConnect the two segments of each shelf (A) using the included screws and nuts (B).Leave the screws sligh

Strona 12

4MountingcontinuedConnect the shelved sections from two UPSRMRII kits (A) to the unshelved sections(B) using the included screws and nuts (C). Note: T

Strona 13 - Operation

Mount the shelved sections (A) of your UPSRMRII kit on the back side of your rack.Mount them in the lowest available space of your rack with with the

Strona 14

6FeaturesFamiliarize yourself with the location and function of the front and rear panel features before installing and operating your UPS.UPS Front P

Strona 15

7FeaturescontinuedUPS Rear PanelEPOACC.RS-232 DRY CONTACTAC INPUTAC OUTPUT BREAKERAC INPUT BREAKEREXTERNAL BATTERY INPUT 240VDC CAUTION:DO NOT DISCONN

Strona 16 - 2-Year Limited Warranty

8FeaturescontinuedUPS Rear Panel1. Output Terminal Block: Use these terminals to connect your UPS to your equipment or to the transformer’s UPS Connec

Strona 17 - Specifications

9Hardwire your utility power source to your UPS’s input.Remove the top of the box covering the UPS’s power terminals. Pass one end of apower cable thr

Komentarze do niniejszej Instrukcji

Brak uwag